Excavator accessories 10333044 Doosan Pilot safety lock solenoid valve coil 280239
Supply Ability
Selling Units: Single item
Single package size: 7X4X5 cm
Single gross weight: 0.300 kg
Product introduction
For Liebherr solenoid coil pilot safety lock iron shell 24V 280239 10333044
Model: For Liebherr
Model: 280239 、10333044
Warranty period: 1 year
Weight: 0.3kg
Specifications: 24V straight insert length 53mm hole distance 16mm
Single bit: one
Packaging: Neutral
Brand: FLYING BULL
The movable core in the solenoid valve coil is attracted by the coil when the valve is energized, driving the valve core to move, thus changing the on-state of the valve; The so-called dry or wet type only refers to the working environment of the coil, and there is no big difference in the valve action; However, the inductance of a hollow coil and the inductance after the addition of an iron core in the coil is different, the former is small, the latter is large, when the coil through alternating current, the impedance generated by the coil is not the same, for the same coil, plus the same frequency of alternating current, the inductance will vary with the core position, that is, its impedance varies with the core position, the impedance is small. The current flowing through the coil will increase.
Cause of solenoid coil burn out
The simplest way is to use a multimeter to measure the resistance of the solenoid valve. The resistance of the coil should be around 100 ohms! If the resistance of the coil is infinite, it means that it is broken. If the measured resistance is normal, it doesn't mean that the coil must be good. You should also find a small screwdriver near the metal rod passing through the solenoid valve coil, and then electrify the solenoid valve. If you feel magnetism, then the solenoid valve coil is good, otherwise it is bad.